3.5.7.1.95. Data Port Path - #DAPT
#DAPT – Data Port Path
AT#DAPT= <psd
port>[,<csd port>]
Set command sets the port to transmit and receive data when data call is
connected by ATD command
Parameter
<psd_port> - packet switched data port
0 – The port ATD is issued ( factory default )
1 – UART Data Port
2 – Telit USB Modem Port
3 – Telit USB Auxiliary Port
<csd_port> - circuit switched data port
0 – The port ATD is issued ( factory default )
1 – UART Data Port
2 – Telit USB Modem Port
3 – Telit USB Auxiliary Port
AT#DAPT Read command reports current setting value , in the format:
#DAPT: <psd_port>,<csd_port>
AT#DAPT=? Test command reports the supported range of values for parameter
<psd_port> and <csd_port>
Note
This command have no effect on the behavior of FAX call.
3.5.7.1.96. Apply to New Operator Names
#PLMNMODE – Apply to New Operator Names
AT#PLMNMODE=<
mode>
Set command apply to new operator names depending on the parameter
<mode>.
Parameter:
<mode>
0 – previous operator names(factory default)
1 – new operator names
Note : if <mode>=1, AT+COPN command shows new operator names.
Note: Default value for UC864-G AT&T (08.01.127) is 1.
AT#PLMNMODE? Read command returns current value of the parameter <mode>.